Heat Exchange and Transfer home page
Heat Exchange Applications Inquiry
Heat Exchange and Transfer Service
Request Information or a Quote

Thermal Fluid System Application Data Sheet

FOR ROLLS

Please Fill out the information below, or Contact:
Mary Ellen Wilkeson
Email: customerservice@heat-inc.com
Phone: (412) 446-1177

A. Customer Information

*Required
Company Name:
Company Address:
 
*Contact Name:
*Email Address:
*Phone: Fax:

B. Process Equipment Parameters
User Equipment Description (e.g. machine type, calender, laminator, etc.):
Number of Rolls: , Are the rolls the same? Yes    No
#1 Roll Material:
  Roll Dimensions: Length: in, Diameter: Weight: lbs.
  Roll's fluid volume: gallons, Or thickness of flow path in.
  Percent Wrap: %, Pressure drop through Roll: psi @ gpm
  Rotary Joint connection sizes: " inlet port, and " outlet port
#2 Roll Material:
  Roll Dimensions: Length: in, Diameter: Weight: lbs.
  Roll's fluid volume: gallons, Or thickness of flow path in.
  Percent Wrap: %, Pressure drop through Roll: psi @ gpm
  Rotary Joint connection sizes: " inlet port, and " outlet port

C. Product specifications:(Complete for each material)
#1 Material name:
  Specific Heat: BTU/lb-°F
  Processing Rate : lb/hr, Thickness: in., Density: lb/ft3
  Initial temperature: °F, Final Temperature °F
#2 Material name:
  Specific Heat: BTU/lb-°F
  Processing Rate : lb/hr, Thickness: in., Density: lb/ft3
  Initial temperature: °F, Final Temperature °F @ °F/min

D. Process Parameters:
Operating temperature of the user equipment: Initial: °F, Maximum °F
Heat up time required for initial start-up: hours
What temperature gradient is required across the roll? °F
Web Speed: ft/min, Web width:
Is cooling required? Yes No
Cooling required for: set point      cool down      exothermic (check one or more)
Cooling control: On/Off      Proportional
Cooler Sizing (if applicable):
Continuous: Remove Btu/hr @ °F using (media*) from °F to °F
(* - Air, water, chilled, glycol, etc.)

E. Thermal Fluid System Parameters:
Heat Transfer Fluid:
Operating Fluid Temperature Range:
Minimum: °F, Maximum: °F, Normal Operating: °F
Heater Sizing: or Btu/hr (if known)
Flow Rate: @ ft of Head (if known)
Should the system be an    Open Skid    Sheet Metal Enclosed

F. Installation Parameters:
Distance between fluid system and process equipment:
Horizontal: ft.   Vertical : ft.
Piping between fluid system and process equipment:
Size: in.,   Schedule: , Length: ft.
Type of fluid piping insulation: Thickness:
Ambient temperature at installation site: Minimum: °F Maximum: °F
Area classification or NEMA rating:
If hazardous, is air purging acceptable? Yes    No

G. Available Utilities:
Power Available: Volts, Phase, Hz, Amps
Air: °F psig, SCFM  
Nitrogen: °F psig, SCFM  
Steam: °F psig, lb/hr  
Water: °F psig, gpm  
Thermal Oil: °F psig, gpm, Type
Other: °F psig, gpm, Type

H. Please list any requirements that may affect the design of this equipment:

  


 
 
Copyright © 2010 Heat Exchange and Transfer, Inc.
  Terms of use / Privacy statement